ProAct Services can provide high purity water for LNG Tank Hydrotests.

Water sources include sea water, estuary water, or groundwater. ProAct
Services can mobilize reverse osmosis skids, sand filters, bag filters,
carbon filtration equipment with the capacity to deliver up to 2,000 gallons
per minute of high purity water. We can also efficiently remove the
water when the testing is complete and place it in adjacent tanks if
required.
Parameter
Limitation
pH 6 - 8 s.u.
Electric
Conduction Ratio Below 500
ms/cm @25
degree’s C
Chloride
Content Below 200 ppm
Water Soluble Sulfate (SO42-) Below 200 ppm
Iron Content (Fe)
targeted Below 1.0 ppm
Ammonia ion content (NH4+) Nearly
0 ppm
Chemical Oxygen Demand (CODMn) Below 15 ppm
ProAct
custom designs the water treatment system for each project with extra
capacity to guarantee delivery of up to 26 million gallons of high purity
water in less than 15 days. This extra capacity insures that hydrotest
water production and transfer activities are on schedule and do not
interfere with the tank construction time table.
·