"Full Service" Water Treatment specialists

rapid response 

 24 hour Response

 Pipeline and Storage Tank Services  Hydrotest Water Treatment

Storage Tank Hydrotest & Degassing

LNG Tank Hydrotest

Specialists

 

3,000 GPM Pipeline Discharge Water Treatment

Mobile carbon and sand filters were used to filter water at a flow rate of 3,000 gallons per minute to keep up with the water removal rate from the pipeline in California. Water was pushed out of the pipeline into a series of frac tanks and then treated by ProAct.

A problem with the suspended solids in the sand filter back wash water was encountered early in the project. The solids were not settling before the next back wash event. ProAct responded within 24 hours to install a coagulating polymer injection system to speed the removal of solids from the back wash water. This modification restored the ability to treat water at 3,000 gpm.  

Volume:  327,441 barrels Flow Rate:  71 barrels per minute
              13.8 M gallons                  3,000 gallons per minute
Discharge Monitored for:  
         Iron, Oil & Grease, Total Suspended Solids, Total Dissolved Solids, Chlorine and pH  
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact: Peter Horrall 210-862-6467 or horrall@proact-usa.com                   

We do it right, and we do it right NOW!             

Water Treatment
Projects
Rental Equipment
Construction Water
Tank Degassing
LNG Hydrotest Water
Safety & Health
Project Photo Gallery

   [Home]  [About ProAct]  [Contact ProAct]   [Terms & Conditions]

Send mail to skar@proact-usa.com with questions or comments about this web site.
Copyright © 2008 ProAct Services Corporation
Last modified: 06/26/08